Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Arch. cardiol. Méx ; 93(1): 69-76, ene.-mar. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1429707

ABSTRACT

Abstract Purpose: The Tpeak-Tend interval of the T wave has emerged as a new electrocardiographic marker of increased transmural dispersion of ventricular repolarization. We aimed to determine the presence of cardiac conduction system disorders in patients with systemic arterial hypertension (SAH) who have altered Tpeak-Tend interval of the T wave. Methods: The 67 patients with SAH were divided into two groups. Those with prolonged (≥ 77 ms) Tpeak-Tend intervals, 21 (31%) patients were in the study group. Those with normal (< 77 ms) Tpeak-Tend intervals, 46 (69%) patients were in the control group. Alteration of ventricular repolarization manifested as a prolongation of the Tpeak-Tend interval was detected by computerized electrocardiographic analysis tools. Results: The median value of QRS complex duration was significantly wider in the study group as compared to the control group (110 ± 12 ms vs. 94 ± 8 ms p < 0.001). There was a significantly greater incidence of left anterior hemiblock in the study group (14% vs. 0% p < 0.04). The median value of the QTc interval was significantly greater in the study group (440 ± 26 vs. 422 ± 15 p < 0.01). There was a significantly greater incidence of patients with prolonged QTc interval in the study group (33% vs. 11% p < 0.02). The median value of the Tpeak-Tend interval was significantly greater in the study group (84 ± 5 ms vs. 65 ± 4 ms p < 0.001), as well as, the Tpeak-Tend/QTc ratio in the study group (0.19 ± 0.1 vs. 0.16 ± 0.1 p < 0.001). Conclusion: There is a significantly greater ventricular repolarization disorders and abnormalities of the cardiac conduction system in SAH patients who possess altered Tpeak-Tend interval of the T wave.


Resumen Objetivo: El intervalo Tpico-Tfinal de la onda T es un marcador electrocardiográfico de la dispersión transmural aumentada de la repolarización ventricular. Investigamos la presencia de trastornos del sistema de conducción cardíaca en pacientes con hipertensión arterial sistémica (HA) que poseen alterado el intervalo Tpico-Tfinal de la onda T. Métodos: Los 67 pacientes con HA fueron divididos en dos grupos. Aquellos con intervalos de Tpico-Tfinal prolongados (≥ 77 ms), 21 (31%) pacientes (grupo de estudio). Aquellos con intervalos normales (< 77 ms) Tpico-Tfinal, 46 (69%) pacientes (grupo control). Los intervalos Tpico-Tfinal fueron medidos por herramientas de análisis electrocardiográfico computarizado. Resultados: El valor mediano de la duración del complejo QRS fue significativamente más amplio en el grupo de estudio (110 ± 12 ms vs. 94 ± 8 ms p < 0.001). Hubo una incidencia significativamente mayor de hemibloqueo anterior izquierdo en el grupo de estudio (14% vs. 0% p < 0.04). El valor mediano del intervalo QTc fue significativamente mayor en el grupo de estudio (440 ± 26 vs. 422 ± 15 p < 0.01). Hubo una incidencia significativamente mayor de pacientes con intervalo QTc prolongado en el grupo de estudio (33% vs. 11% p < 0.02). El valor mediano del intervalo Tpico-Tfinal fue significativamente mayor en el grupo de estudio (84 ± 5 ms vs. 65 ± 4 ms p < 0.001), así como el cociente Tpico-Tfinal/QTc (0.19 ± 0.1 vs. 0.16 ± 0.1 p < 0.001). Conclusión: Existe una alteración de la repolarización ventricular significativamente mayor y anomalías del sistema de conducción cardíaca en pacientes con HA que poseen alteración del intervalo Tpico-Tfinal de la onda T.

2.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1386323

ABSTRACT

RESUMEN Las características anisotrópicas ocasionadas por un miocardio auricular patológico pueden jugar un papel importante en la creación de circuitos de reentrada al causar propagación no homogénea y discontinua del impulso en el miocardio auricular. Este miocardio auricular alterado puede generar bloqueo unidireccional, retraso de la conducción y ritmos auriculares reentrantes. En estas condiciones la onda P del electrocardiograma (ECG) puede mostrar alteraciones que pueden asociarse con arritmias auriculares y fibrilación auricular (FA). La dispersión de la onda P (DP) se considera un marcador no invasivo del ECG para el remodelado auricular y es predictor sensible y específico del desarrollo de FA. Se ha demostrado que el aumento de la duración de la onda P y la DP reflejan la prolongación del tiempo de conducción auricular dentro de la aurícula derecha y entre ambas aurículas, y una propagación auricular no homogénea y discontinua de los impulsos sinusales. Un valor de corte de 40 ms de la DP demostró tener una sensibilidad del 83%, una especificidad del 85% y un valor predictivo positivo del 89% para la identificación de pacientes con antecedentes de FA paroxística aislada. Los pacientes con alteración de la morfología de la onda P y dispersión de la onda P en el ECG tienen una gran susceptibilidad a desarrollar FA porque poseen electrogramas endocárdicos auriculares anormalmente prolongados y fraccionados, una duración de onda P significativamente mayor, un tiempo de conducción intraauricular e interauricular significativamente más largo, y una mayor incidencia de inducción de fibrilación auricular sostenida.


ABSTRACT The anisotropic characteristics caused by a pathological atrial myocardium can play an important role in the creation of reentry circuits by causing discontinuous and inhomogeneous impulse propagation in the atrial myocardium. This altered atrial myocardium can lead to unidirectional block, conduction delay, and reentrant atrial rhythms. Under these conditions, the P wave of the electrocardiogram (ECG) can demonstrate alterations that can be associated with atrial arrhythmias and atrial fibrillation (AF). The P-wave dispersion (PD) is considered a non-invasive ECG marker for atrial remodeling and is a sensitive and specific predictor of the development of AF. Increased P wave duration and PD have been shown to reflect prolonged atrial conduction time within the right atrium and between both atria, and discontinuous, inhomogeneous atrial propagation of sinus impulses. A cutoff value of 40 ms for PD was shown to have a sensitivity of 83%, a specificity of 85%, and a positive predictive value of 89% for the identification of patients with a history of isolated paroxysmal AF. Patients with abnormal P wave morphology and P wave dispersion on the ECG are highly susceptible to developing AF because they have abnormally prolonged and fractionated atrial endocardial electrograms, significantly longer P wave duration, and significantly longer intra-atrial and inter-atrial conduction time, and a higher incidence of sustained atrial fibrillation induction.

3.
Mem. Inst. Invest. Cienc. Salud (Impr.) ; 16(2): 79-83, Ago. 2018. tab, ilus
Article in Spanish | LILACS, BDNPAR | ID: biblio-997982

ABSTRACT

Uno de los factores condicionantes del peso corporal es la percepción que la persona tiene de su imagen corporal. El objetivo fue conocer la percepción de imagen corporal según el índice de masa corporal (IMC) en 107 Médicos Residentes del Hospital de Clínicas.Se utilizó un diseño observacional descriptivo de corte transverso. Se exploraron las variables edad, sexo, circunferencia abdominal, peso, talla, IMC, percepción del peso corporal. La circunferencia abdominal fue de riesgo elevado en 37% de los varones y en 16% de las mujeres, de riesgo muy elevado en 13% de varones y en 29% de las mujeres (p=0,009). En cuanto al IMC la media fue de 25,7±4,6; estando en peso normal el 45% y en sobrepeso el 43%. Se encontró más mujeres con peso normal (63% vs 28%). Los varones presentan más sobrepeso (61% vs 28%) (p=0,0009). En cuanto a la percepción del peso corporal se perciben con obesidad 23%; con sobrepeso 47% y con peso normal 28%. Cruzando los datos con los IMC verdaderos, tenemos que el 43% no tiene la percepción real de acuerdo a su IMC. La concordancia en cuanto a IMC real y la percepción es del 63%. Casi la mitad de los residentes estudiados no tiene la percepción real de acuerdo a su IMC. La percepción de obesidad es mayor en mujeres que en hombres acorde a su IMC real. Se requiere de más investigaciones en referencia al tema aplicándolo a toda la población del hospital para crear medidas educativas de oportuna intervención en la salud del personal sanitario(AU)


The perception of their own body image that a person has is a conditioning factor of the body weight. We aimed to know the perception of body image assessing the body mass index (BMI) in 107 medical residents of the Clinical Hospital. We utilized a descriptive observational design to evaluate multiple variables like gender, age, abdominal diameter, weight, height, body mass index, and perception of body weight. The abdominal diameter was of high risk in 37% of males and 16% in females, and of very high risk in 13% of males and in 29% of females (p=0,009). The medium BMI was 25,7±4,6. There was a normal BMI in 45% of the subjects and overweight in 43%. There were more female with normal weight than male (63% vs 28%), and there were more overweight male than female (61% vs 28%) (p=0,0009). Considering the perception of body weight, 23% perceive themselves to be obese, 47% with overweight, and 28% with normal body weight. Comparing this perception with real BMI, we observed that 43% of the subjects do not have a real perception according to the BMI. The agreement between real BMI and the image perception is 63%. Almost half of the medical residents studied do not have a real body weight perception according to BMI. The perception of obesity is greater in women than in men according to the real BMI. There is a necessity of larger studies including the total population of the hospital to create educational measures for timely intervention in the health of hospital personal(AU)


Subject(s)
Humans , Male , Female , Adult , Physicians , Body Image , Body Mass Index , Cross-Sectional Studies , Risk Assessment
SELECTION OF CITATIONS
SEARCH DETAIL